48V 50ah High Energy Density Solar Energy Storage Lithium Battery

US$626.00-740.00 1 Piece (MOQ)
Port:
Shanghai, China
Production Capacity:
50000PCS/Week
Payment Terms:
L/C, T/T, D/P, Western Union, Paypal, Money Gram

WEUP Power Co., Ltd.

Anhui, China

Rating: 5.0/5

Last Login Date:

May 26, 2025

Business Type:

Manufacturer/Factory

Main Products:

Solar Panel, Solar Energy System, Inverter, Solar Battery, BIPV, Lithium Battery Pack, N-Type Solar Panel, Shingled Solar Panel, Flexible Solar Panel, Topcon Solar Panel

Find Similar Products

Product Description

Company Info

Basic Info.

Model NO.
48V 50ah
Type
Li-ion Battery
Cathode Material
LFP
Rechargeable
Yes
Size
Normal
Battery Type
LiFePO4(LFP)
Nominal Capacity(Wh)
2560wh
Design Life
10+ Years (25 /77f )
Dimension(mm)
440*133*400
Charge/Discharge Current(a)
25A(Recommended)
Power Consumption
<2W (Work) <100MW(Sleep)
Monitoring Parameters
System Voltage, Current, Cell Voltage, Cell Temper
Soc
Intelligent Algorithm
Communication
Can/RS-485/RS-232
Operating Temperature Range
-10ºC~50ºC
Humidity
15%~85% (No Condensing
Trademark
WEUP
Transport Package
Carton and Pallets
Specification
440*133*400mm/27kg
Origin
China
HS Code
850760009

Product Description


 
 
Normal
ModelWP4850
Battery TypeLifePO4(LFP)
Nominal Voltage(V)51.2 V
Nominal Capacity(WH)2560WH
Usable Capacity(WH)2048WH
Design Life10+ Years (25ºC/77F )
Physical
Dimension(mm)440*133 *400
Weight(kg)27
Electrical
Cycle Life>6000, 25ºC,DOD80%
Discharge Voltage(V)40~58.4
Charge Voltage(V)56~58.4
Charge/Discharge Current(A)25A(Recommended)
50A(Max)
Internal Resistance≤30mΩ
BMS
Power Consumption<2W (Work) <100mW(Sleep)
Monitoring ParametersSystem voltage, Current, cell voltage, cell temperature, module temperature
SOCIntelligent algorithm
CommunicationCAN/RS-485/RS-232
Operation
Operating Temperature Range-10ºC~50ºC
Transport or Storage Temperature Range-20ºC~45ºC
Humidity15%~85% (No Condensing)

Trouble Shooting Steps                                                                                           
1 Problem determination based on:
1) Whether the battery can be truned on.
2) If battery is turned on, check the red light is off, flashing or lighting:
3) If the red light is off, check whether the battery can be charged/discharged.
2 Perliminary determination steps:
1) Battery cannot be turned on, switch on the lights are all no lighting or flashing. If the battery extemal switch is ON, the RUN light is flashing, and the extemal power supply voltage is 48V or more, the battery still unable to turn on, please contact distributor.
2) The battery can be turned on, but red light is lighting, and cannot be charged or discharged, red light is lighting, that means system is abnormal,please check values as following:
3) Temperature: Above 50ºC  or under -10ºC, the battery could not work.
Solution: to move battery to the normal operating temperature range between -10ºC and 50ºC.
4) Current: If current is larger than 100A, battery protection will turn on.
Solution: Check whether current is too large or not, if it is, to change the settings on power supply side.
5) High Voltage: If charging voltage above 54.75V, battery protection will turn on.
Solution: Check whether voltage is too high or not, if it is, to change the settings on power supply side.
6) Low Voltage: When the battery discharges to 37.5V or less, battery protection will turn on. Solution: Charge the battery for some time, the red light will turn off.
Excluding the four points above, if the faulty is still cannot be located, turn off battery and
repair.
Send your message to this supplier
Mr. David Dai

Post a Sourcing Request Now

People who liked this also liked